System Over View:
NURSE CALL MONITORING SYSTEM – Each bed is provided with a call station board consisting of a Bed push confirmation light and re-set push. The patient can make a call from the push switch. On receipt of the call at the Digital Display Board, the Confirmation Light on the Call Station will be on. This ensures that there is no problem in wiring.
The call received at the Display Board can only be re-set by the attending nurse from the re-set push provided at the bedside of the patient (Call Station Board). On attending the call, the confirmation light and the bed number on the monitor will be switched off.
If any call remains pending over a set period the particular number will be highlighted by Flushing the digit & buzzer installed at the floor in charge/ matron will be activated. This will help in avoiding any negligence in services.
The system will comprise of
a) Call Station Board,
b) Door Indicator,
c) Digital Display board,
d) Data Logger Card
e) UPS system.
Call Station Board: consists of Bed push confirmation light and re-set push. It is designed for a standard modular box. |
Door Indicator: consists of a cluster of LEDs mounted in the specially designed cabinet. It has a Tangle/ Round Red acrylic cover. It may be installed outside the room. It starts flushing if any call in the room is pending. This helps the Nurses move by to attend immediately even before going to the Nurses Station. |
Call Indicator Board: The Call Indicator Board is to be installed at the Nurse center. Call received from any bed will be displayed by the respective indicator with a Green LED against the bed number marked |
Digital Display board: The Digital display board is called a monitor console which is installed at the Nurse center. All Calls received from any bed will be displayed by the respective bed number in a 3-digit display. Select the display board as per the total no of beds, toilets, etc to be covered by one Nurse Station. It has a soft buzzer which alerts the attendment on receipt of any new calls. |
Data Logger Card: This is an add-on card to connect the display board with any standard computer. With this add-on card, all events can be recorded. The call received from each bed is stamped with the time of call and on attendance also it is stamped with time. Data thus generated helps the Hospital Management in making appropriate decisions. The card is supported with specially developed software which is installed in the computer. |
UPS: The system has its own specially designed UPS. It consists of an SMF type 12 v 7 ah battery, automatic battery charger, and allied accessories. |
Unique advantages are
Low voltage operation: The incoming mains are converted to 12 V.D.C. in the Power Supply section and the patient is not put in danger even due to accidental snatching of wires.
Digital Display of Bed Nos: with 2-3 digit Bright LED displays, the bed number can be easily noticed from a distance.
Non-attendance timer: Each call received activates a built-in timer and after a specified time, it activates a Buzzer.
Battery backup: To facilitate making calls even during a power cut, the system is provided with a battery backup.
Re-set at patient’s bed: To re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance.
Cost-effective solution: This system is very cost-effective for installation and maintenance.
Computer Connectivity: with an add-on Card, the system can record each event and help management in making an appropriate and logical decision.
Ordering information BPS D20 / D30 Digital Nurses Call Monitoring System.
Item | Description | Model No. | Quantity required |
Call station Board |
With 3 ” x 3″ MS Box, Acrylic cover, confirmation Light, Re-set push & Bed Push with 2 meter flexible wire | BNCM-PB1 | each bed = 1 set |
With 3 ” x 3″ MS Box, Modular cover, confirmation Light, Re-set push & Bed Push with 2 meter flexible wire | BNCM-PB2 | (PB1 or PB2) | |
Door Indicator |
with 8 Nos Red LEDs, Red Acrylic cover suitable for connecting up to 8 beds in one room | BNCM-DU-1 | Optional for each room |
with 3 color LEDs, Flash/ study / Off functions, Acknowledge Push, and Acrylic cover suitable for connecting up to 4 beds in one room | BNCM-DU-2 | ||
Digital Display Board with 2 digit display |
with one No 2 Digit display card, Acrylic cover, in MS box of 275 x 125 x 50 mm | BNCM-D2CA | up to 6 beds |
with two No. 2 Digit display cards, Acrylic cover, in MS box of 275 x 225 x 50 mm | BNCM-D2CB | up to 12 beds | |
with three No.2 Digit display cards, Acrylic cover, in MS box of 300 x 325 x 50 mm | BNCM-D2CC | up to 18 beds | |
with four No. 2 Digit display cards, Acrylic cover, in MS box of 300 x 460 x 50 mm | BNCM-D2CD | up to 24 beds | |
with five No.2 Digit display cards, Acrylic cover, in MS box of 350 x 550 x 50 mm | BNCM-D2CE | up to 30 beds | |
with six No.2 Digit display cards, Acrylic cover, in MS box of 350 x 6000 x 50 mm | BNCM-D2CF | up to 36 beds | |
Digital Display Board with 3 digit display |
with one No.3 Digit display card, Acrylic cover, in MS box of 300 x 125 x 50 mm | BNCM-D3CA | up to 5 beds |
with two No.3 Digit display cards, Acrylic cover, in MS box of 300 x 225 x 50 mm | BNCM-D3CB | up to 10 beds | |
with three No.3 Digit display cards, Acrylic cover, in MS box of 300 x 350 x 50 mm | BNCM-D3CC | up to 15 beds | |
with four No.3 Digit display cards, Acrylic cover, in MS box of 300 x 450 x 50 mm | BNCM-D3CD | up to 20 beds | |
with five No.3 Digit display cards, Acrylic cover, in MS box of 300 x 550 x 50 mm | BNCM-D3CE | up to 25 beds | |
with six No. 3 Digit display cards, Acrylic cover, in MS box of 600 x 475 x 50 mm | BNCM-D3CF | up to 30 beds | |
Data Logger Card |
Computer interface card with software fitted in the enclosure | BNCM-DLC-1 | up to 36 beds |
UPS system | Power supply with Automatic Battery charger, SMF 12 V. 7 AH battery | BNCMUPS1 | Up to 36 beds = 1 set |
Wires from bed to call station |
2 pair telephone wire | as per distance from beds to call station |